Data
{
"name": "CHS",
"pic_path": "\/tool\/tag\/pic\/chs.jpg",
"product_system_str": "Bus Converter\u30fbPower Module type",
"environment_mark_str": "RoHS",
"explanation": "Rated Input\uff1aDC18 - 36V, DC36 - 76V<br \/>Rated Output Wattage\uff1a60 - 700W",
"patent": "• High efficiency 96% (CHS7004812H)<br \/>• Compact DC-DC Converter, \"BRICK SIZE\" which has been standard size for Telecommunication Market<br \/>• High density<br \/>• High reliability: not built-in aluminum and tantalum electrolytic capacitor<br \/>• Built-in overcurrent, overvoltage and thermal protection circuits<br \/>• Built-in remote ON\/OFF",
"free_guarantee_term_unit": "-year",
"free_guarantee_term_specification": "5"
}Mapping
{
"power_series": {
"name": {
"type": "sortable",
"field": "title"
},
"pic_path": {
"type": "plaintext",
"field": "cs_pic_path"
},
"explanation": {
"type": "plaintext",
"field": "description"
},
"patent": {
"type": "plaintext",
"field": "cs_patent"
},
"product_system_str": {
"type": "plaintext",
"field": "cs_product_system"
},
"environment_mark_str": {
"type": "plaintext",
"field": "cs_environment_mark"
},
"free_guarantee_term_unit": {
"type": "plaintext",
"field": "cs_free_guarantee_term_unit"
},
"free_guarantee_term_specification": {
"type": "plaintext",
"field": "cs_free_guarantee_term_specification"
},
"note": {
"type": "plaintext",
"field": "cs_note"
}
}
}
Data
[
{
"name": "CHS60",
"pic_path": "\/tool\/tag\/pic\/chs60.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC36 - 76V<br \/>Rated Output Wattage\uff1a60W<br \/>Output Voltage\uff1a3.3V,5V,12V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air"
},
{
"name": "CHS80",
"pic_path": "\/tool\/tag\/pic\/chs80.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC36 - 76V<br \/>Rated Output Wattage\uff1a80W<br \/>Output Voltage\uff1a3.3V,5V,12V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air"
},
{
"name": "CHS120",
"pic_path": "\/tool\/tag\/pic\/chs120.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC18 - 36V,DC36 - 76V<br \/>Rated Output Wattage\uff1a120W<br \/>Output Voltage\uff1a3.3V,5V,12V,15V,24V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air\/Conduction"
},
{
"name": "CHS200",
"pic_path": "\/tool\/tag\/pic\/chs200.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC36 - 76V<br \/>Rated Output Wattage\uff1a200W<br \/>Output Voltage\uff1a3.3V,5V,12V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air\/Conduction"
},
{
"name": "CHS300",
"pic_path": "\/tool\/tag\/pic\/chs300.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC18 - 36V, DC36 - 76V<br \/>Rated Output Wattage\uff1a300W<br \/>Output Voltage\uff1a5V,10V,12V,15V,24V,28V,32V,48V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air\/Conduction"
},
{
"name": "CHS380",
"pic_path": "\/tool\/tag\/pic\/chs380.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC36 - 76V<br \/>Rated Output Wattage\uff1a380W<br \/>Output Voltage\uff1a10V,12V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air\/Conduction"
},
{
"name": "CHS400",
"pic_path": "\/tool\/tag\/pic\/chs400.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling, Conduction Cooling",
"explanation": "Rated Input\uff1aDC18 - 36V,DC36 - 76V<br \/>Rated Output Wattage\uff1a318 - 400W<br \/>Output Voltage\uff1a10V,12V,15V,24V,28V,32V,48V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air\/Conduction"
},
{
"name": "CHS500",
"pic_path": "\/tool\/tag\/pic\/chs500.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC36 - 76V<br \/>Rated Output Wattage\uff1a500W<br \/>Output Voltage\uff1a12V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air\/Conduction"
},
{
"name": "CHS700",
"pic_path": "\/tool\/tag\/pic\/chs700.jpg",
"cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling",
"explanation": "Rated Input\uff1aDC36 - 76V<br \/>Rated Output Wattage\uff1a700W<br \/>Output Voltage\uff1a12V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_CHS.pdf",
"struct_cool": "Convection\/Forced air\/Conduction"
}
]Mapping
{
"power_models": [
{
"name": {
"type": "sortable",
"field": "title"
},
"pic_path": {
"type": "plaintext",
"field": "csm_pic_path"
},
"explanation": {
"type": "wikitext",
"field": "description"
},
"cool_str": {
"type": "wikitext",
"field": "csm_cool_str"
},
"struct_cool": {
"type": "wikitext",
"field": "csm_struct_cool"
},
"catalog_pdf": {
"type": "plaintext",
"field": "csm_ catalog_pdf"
}
}
]
}