Data
{
"name": "TUNS",
"pic_path": "\/tool\/tag\/pic\/tuns.jpg",
"product_system_str": "Bus Converter\u30fbPower Module type",
"environment_mark_str": "RoHS",
"explanation": "Rated Input: AC85 - 264V<br \/>TUNS1200F AC85 \uff5e 305V<br \/>Rated Output Wattage: 50 - 1200W",
"patent": "\u2022 AC-DC converter with PFC which is suitable for conduction cooling.<br \/>\u2022 High density<br \/>\u2022 High reliability: not built-in aluminum and tantalum electrolytic capacitor<br \/>\u2022 Built-in overcurrent, overvoltage and thermal protection circuits<br \/><br \/> < TUNS50F\/100F\/300F\/500F\/700F > <br \/> \u2022 Universal input voltage (AC85 - 264V)<br \/> \u2022 Peak current (TUNS500F) <br \/><br \/> < TUNS1200F > <br \/> \u2022 Wide input voltage (AC85 - 305V)<br \/> \u2022 For medical electric equipment<br \/> \u2022 Medical Isolation Grade 2MOOP<br \/> \u2022 Parallel operation possible<br \/> \u2022 N+1 Parallel Redundancy Operation possible<br \/> \u2022 Constant current regulation<br \/> \u2022 Output voltage can be varied to near 0V<br \/> \u2022 Complies with SEMI F-47 ",
"note": "*Avoid short circuit between +BC\/R and -BC. It may cause the failure of inside components.<br \/>*Keep TRM, VTRM open, if output voltage adjustment is not necessary.<br \/>*If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S.<br \/>\uff08TUNS100\/300\/500\/700\/1200\uff09<br \/>",
"free_guarantee_term_unit": "-year",
"free_guarantee_term_specification": "5"
}Mapping
{
"power_series": {
"name": {
"type": "sortable",
"field": "title"
},
"pic_path": {
"type": "plaintext",
"field": "cs_pic_path"
},
"explanation": {
"type": "plaintext",
"field": "description"
},
"patent": {
"type": "plaintext",
"field": "cs_patent"
},
"product_system_str": {
"type": "plaintext",
"field": "cs_product_system"
},
"environment_mark_str": {
"type": "plaintext",
"field": "cs_environment_mark"
},
"free_guarantee_term_unit": {
"type": "plaintext",
"field": "cs_free_guarantee_term_unit"
},
"free_guarantee_term_specification": {
"type": "plaintext",
"field": "cs_free_guarantee_term_specification"
},
"note": {
"type": "plaintext",
"field": "cs_note"
}
}
}
Data
[
{
"name": "TUNS50F",
"pic_path": "\/tool\/tag\/pic\/tuns50f.jpg",
"cool_str": "Conduction Cooling",
"explanation": "Rated Input: AC85 - 264V 1Φ<br \/>Rated Output Wattage: 50W<br \/>Rated Output Voltage: 5V,12V,24V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_TU.pdf",
"struct_cool": "Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)"
},
{
"name": "TUNS100F",
"pic_path": "\/tool\/tag\/pic\/tuns100f.jpg",
"cool_str": "Conduction Cooling",
"explanation": "Rated Input: AC85 - 264V 1Φ<br \/>Rated Output Wattage: 100W<br \/>Rated Output Voltage: 5V,12V,24V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_TU.pdf",
"struct_cool": "Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)"
},
{
"name": "TUNS300F",
"pic_path": "\/tool\/tag\/pic\/tuns300f.jpg",
"cool_str": "Conduction Cooling",
"explanation": "Rated Input: AC85 - 264V 1Φ<br \/>Rated Output Wattage: 300W<br \/>Rated Output Voltage: 12V,28V,48V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_TU.pdf",
"struct_cool": "Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)"
},
{
"name": "TUNS500F",
"pic_path": "\/tool\/tag\/pic\/tuns500f.jpg",
"cool_str": "Conduction Cooling",
"explanation": "Rated Input: AC85 - 264V 1Φ<br \/>Rated Output Wattage: 500W<br \/>Rated Output Voltage: 12V,28V,48V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_TU.pdf",
"struct_cool": "Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)"
},
{
"name": "TUNS700F",
"pic_path": "\/tool\/tag\/pic\/tuns700f.jpg",
"cool_str": "Conduction Cooling",
"explanation": "Rated Input: AC85 - 264V 1Φ<br \/>Rated Output Wattage: 700W<br \/>Rated Output Voltage: 12V,28V,48V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_TU.pdf",
"struct_cool": "Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)"
},
{
"name": "TUNS700F-P",
"pic_path": "\/tool\/tag\/pic\/tuns700f.jpg",
"cool_str": "Conduction Cooling",
"explanation": "Rated Input: AC85 - 264V 1Φ<br \/>Rated Output Wattage: 700W<br \/>Rated Output Voltage: 12V,28V,48V<br \/>*Output voltage trimming disabled.<br \/>*Remote sensing disabled",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_TU.pdf",
"struct_cool": "Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)"
},
{
"name": "TUNS1200F",
"pic_path": "\/tool\/tag\/pic\/tuns1200f.jpg",
"cool_str": "Conduction Cooling",
"explanation": "Rated Input: AC85 - 305V 1Φ<br \/>Rated Output Wattage: 1200W<br \/>Rated Output Voltage: 12V, 28V, 48V, 65V",
"catalog_pdf": "\/tool\/tag\/pdf\/SFE_TU.pdf",
"struct_cool": "Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)"
}
]Mapping
{
"power_models": [
{
"name": {
"type": "sortable",
"field": "title"
},
"pic_path": {
"type": "plaintext",
"field": "csm_pic_path"
},
"explanation": {
"type": "wikitext",
"field": "description"
},
"cool_str": {
"type": "wikitext",
"field": "csm_cool_str"
},
"struct_cool": {
"type": "wikitext",
"field": "csm_struct_cool"
},
"catalog_pdf": {
"type": "plaintext",
"field": "csm_ catalog_pdf"
}
}
]
}