To Be Discontinued
To be discontinued in
PBA10F/15F/30F/50F/100F/150F/300F/600F: October 2028
PBA75F: April 2029
PBA1000F/1500F: NRND
Options
PB(1) A(2) 1500(3) T(4) - 5(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current
U: Operation stop voltage is set at a lower value
F1: With Long-Life fan
F3: Reverse air exhaust type
F4: Low speed fan
Refer to instruction manual 7.1.
| Basic Specification | PBA1500T-5 | PBA1500T-12 | PBA1500T-24 | PBA1500T-48 |
|---|---|---|---|---|
| Check Stock | Check Stock | Check Stock | Check Stock | |
| Input Voltage Range | AC170 - 264V 3Φ | AC170 - 264V 3Φ | ||
| Output Voltage / Current | 5V 300A | 12V 125A | 24V 70A (105) A | 48V 35A |
| Output Power | 1500W | 1680W | ||
| Output Voltage Adj Range | 3.96 - 6.00V | 8.25 - 13.20V | 16.50 - 26.40V | 38.40 - 56.00V |
| Operating Temp (°C) | -20 to +71℃ (Required Derating) , 20 - 90%RH (Non condensing) | -20 to +71℃ (Required Derating) , 20 - 90%RH (Non condensing) | ||
| Cooling Method | Forced cooling (internal fan) | Forced cooling (internal fan) | ||
| Dimensions (W x H x D) | 178x61x268mm (without terminal block and screw) | 178x61x268mm (without terminal block and screw) | ||
| Safety Agency Approvals | UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN |
UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN |
||
| Technical Data | PBA1500T-5 | PBA1500T-12 | PBA1500T-24 | PBA1500T-48 |
| Performance Data | ||||
| EMC Data | ||||
| Expected Life | ||||
| MTBF | ||||
| Reliability Data | ||||