To Be Discontinued
To be discontinued in
PBA10F/15F/30F/50F/100F/150F/300F/600F: October 2028
PBA75F: April 2029
PBA1000F/1500F: NRND
Options
PB(1) A(2) 10(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current
E: Low leakage current and EMI class A
T: Vertical terminal block
J1: VH (J.S.T.) connector type
N: with Cover (UL508 is acquired)
N1: with DIN rail and Cover
V: Output voltage setting potentiometer externally
| Basic Specification | PBA10F-5 | PBA10F-12 | PBA10F-24 |
|---|---|---|---|
| Check Stock | Check Stock | Check Stock | |
| Input Voltage Range | AC85 - 264V 1Φ or DC110 - 370V | ||
| Output Voltage / Current | 5V 2A | 12V 0.9A | 24V 0.5A |
| Output Power | 10W | 10.8W | 12W |
| Output Voltage Adj Range | 4.50 - 5.50V | 10.0 - 13.2V | 19.2 - 27.0V |
| Operating Temp (°C) | -10 to +71℃ (Required Derating) , 20 - 90%RH (Non condensing) | ||
| Cooling Method | Convection | ||
| Dimensions (W x H x D) | 31x78x68mm (without terminal block) | ||
| Safety Agency Approvals | UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN |
||
| Technical Data | PBA10F-5 | PBA10F-12 | PBA10F-24 |
| Performance Data | |||
| EMC Data | |||
| Expected Life | |||
| MTBF | |||
| Reliability Data | |||