Features
- Single phase 250VAC 10A
Ultra high-attenuation and broadband from 9kHz to 10MHz
2-stage filter - Withtand voltage 4,000VAC(Line to ground capacitor code -000 to -471)
Push down type terminal - The terminal cover is retracted inside the unit.
DIN rail installation type is option. - Alternative Energy, Factory Automation, Medical, Communication
Part Number Configuration
NBH(1) - 10(2) - 432(3) - □(4)
(1) Model Name(2) Rated Current
(3) Line to ground capacitor code
Refer to Product Line-up.
* When the line to ground capacitor code is different, the attenuation characteristic is
different.
(4) Options
D:DIN rail installation type
* The dimensions change when the option is set. Refer to External view.