Loading...
 

LEP240F

Discontinued

Options

(For detailed information, please refer to the instruction manual)

  G: Low leakage current
  R: with Remote ON/OFF
  S: with Chassis
  SN: with Chassis & cover
  T: Vertical terminal block
  U: Operating stop voltage is set at a lower value
  Z: with ZT
string(594) "

LEP(1)  240(2)  F(3)  -  24(4)  -  (5)  

(1) Series name
(2) Output wattage
(3) Universal input
(4) Output voltage
(5) Optional
  G: Low leakage current
  R: with Remote ON/OFF
  S: with Chassis
  SN: with Chassis & cover
  T: Vertical terminal block
  U: Operating stop voltage is set at a lower value
  Z: with ZT"

Product Data

  • Datasheet
  • Instruction Manual
  • Accessories
  • Glossary of Technical Terms

Drawings

  • CAD Data (DXF)
  • 3D CAD Data (STEP)
    • Standard model
  • 3D CAD Data (IGES)
    • Standard model

Safety Certificates

  • Safety Approvals
  • EU Declaration of Conformity
  • UK Declaration of Conformity

LEP(1)  240(2)  F(3)  -  24(4)  -  (5)  

(1) Series name
(2) Output wattage
(3) Universal input
(4) Output voltage
(5) Optional
  G: Low leakage current
  R: with Remote ON/OFF
  S: with Chassis
  SN: with Chassis & cover
  T: Vertical terminal block
  U: Operating stop voltage is set at a lower value
  Z: with ZT
Basic Specification LEP240F-24 LEP240F-36 LEP240F-48
  Check Stock Check Stock Check Stock
Input Voltage Range AC85 - 264V 1Φ or DC 120 - 370V
Output Voltage / Current +24V 10A (Peak: 20A) +36V 6.7A (Peak: 13.4A) +48V 5A (Peak: 10A)
Output Power 240W (Peak: 480W) 241.2W (Peak: 482.4W) 240W (Peak: 480W)
Output Voltage Adj Range 21.4 - 26.4V 26.4 - 39.6V 39.6 - 52.8V
Operating Temp (°C) -10 to +70℃, 20 - 90%RH (Non condensing) *
Cooling Method Convection
Dimensions (W x H x D) 95x45x222mm
Safety Agency Approvals UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN and IEC60950-1
Technical Data LEP240F-24 LEP240F-36 LEP240F-48
Performance Data
EMC Data
Expected Life
MTBF
Reliability Data